PDU-RT5002 Military Power Distribution Unit — Rack-Mount Rugged PDU

19-inch 4U rack military PDU distributing energy from three 220 VAC 50 Hz sources (UPS, utility, generator) with prioritized, protected outputs.

Input

3 × 220VAC / 50 Hz

Output

10 × 25A AC/DC

Form factor

4U× 19 inch

Cooling

Fanactive

MIL-STD-461F (EMI/EMC)MIL-STD-810G (Environmental)

Company:ITAR-FreeNCAGE: TM885

Overview

Product and Purpose

The PDU-RT5002 Military Power Distribution Unit is a 19-inch 4U rack solution developed by TEDEG Defence R&D for mission-critical power distribution. It serves command posts, military truck platforms, and fixed military sites by distributing energy from three sources (UPS, utility grid, generator) across ten protected outputs.

Unlike commercial PDUs, PDU-RT5002 combines military EMI/EMC compliance, environmental durability, and remote supervision in one enclosure. Integrators looking for a military power distribution unit get MIL-STD-461F/810G test coverage and series production in Türkiye.

Engineering and Technical Capability

The 10 × 25A AC/DC output configuration matches typical tactical truck architectures: eight to twelve critical loads plus two to four spare channels. Automatic source transfer (utility first, then generator) removes operator intervention during field scenarios.

MIL-STD-461F (CE102, CS101, CS114-116, RE102, RS103) ensures coexistence with onboard radar and radios; TEDEG developed a dedicated filter topology in its Ankara R&D lab. MIL-STD-810G environmental testing covers eleven methods including low pressure, low temperature, humidity, salt fog, vibration, and shock.

Ethernet-based monitoring, 100-entry logging, and granular fault modes accelerate field diagnostics. Breaker-based overcurrent and short-circuit protection isolates faults without collapsing the entire bus.

Technical specifications:

FeatureValue
Part numberPDU-RT5002
Input3 units, 220 VAC 50 Hz (UPS, mains, generator)
Input priority1 – Mains, 2 – Generator
Ready time after power-onMax. 1 minute
OutputUp to 10 units, 25 A AC/DC output
Overcurrent and short-circuit protectionCircuit breaker (AC and DC output circuit breakers)
Fault warning modesSystem fault · AC high · AC low · AC reverse · DC high · DC low · high temperature · low temperature
Log recordingMains voltage, current, frequency, output voltage; last 100 records
PC control interfaceDesktop PC web application (Ethernet)
Front panelBypass switch, AC/DC output circuit breakers, on/off switch, power input and fault indicator, emergency stop button, buzzer and mute button
Dimensions4U, 19" rack type (483 × 172 mm front panel, 602 mm depth; chassis 421 × 602 mm)
MountingRack cabinet mounting with built-in rail
CoolingFan cooling

Typical Application Scenarios

PDU-RT5002 acts as the central PDU on 6×6 air-defence trucks, feeding radar, consoles, and launcher subsystems concurrently. Mobile command containers use it for seamless UPS-to-generator transitions during extended missions.

The unit is equally suited to 24/7 fixed military facilities and maintenance depots requiring multi-source distribution.

Compliance Standards

  • MIL-STD-461F — EMI/EMC: CE102, CS101, CS114, CS115, CS116, RE102, RS103 tests
  • MIL-STD-810G — Environmental durability: low pressure, low temperature, contamination by fluids, solar radiation, rain, humidity, fungus, salt fog, sand and dust, vibration, shock (11 methods total)

TEDEG Advantage

TEDEG Defence moved PDU-RT5002 from concept to series production with an integrated hardware and software team. Standard lead time is 8–12 weeks, reducing programme risk versus 20+ week cycles common among global suppliers.

Domestic manufacturing offers NATO buyers supply-chain flexibility while preserving MIL-STD qualification. Customer variants (channel count, voltage, connectors) extend through modular design without lengthy re-qualification.

Validated by Turkish Defence Primes: The system is supplied as an approved vendor of ASELSAN, Roketsan and the Turkish Ministry of National Defence (MSB). Field-proven service record in tactical truck and fixed-site programmes within the Turkish Armed Forces inventory. NATO supplier registration (NCAGE): TM885. ITAR-Free — no US-origin controlled content.

Production Maturity: The PDU-RT5002 is delivered at day-one production maturity — field-proven topology, certified component sourcing from recognised suppliers, and rapid serial-production capability. Our team carries more than a decade of R&D and production experience in the defence power-distribution segment.

Specifications

Input count & source3 × 220 VAC 50 Hz
Input typesUPS · Utility · Generator
Input priority1. Utility → 2. Generator
Remote controlEthernet, PDU output management
Internal temperatureYes · Thermal system on/off
Output10 × 25 A AC/DC
Overcurrent & short circuitCircuit breaker
Startup timeMax. 1 minute
Fault modesSystem · AC High/Low/Reverse · DC High/Low · Temperature High/Low
Form factor4U × 19 inch (standard rack)
CoolingFan cooling
LoggingUtility V/A/Hz · Output V
Log capacityLast 100 records
PC interfaceDesktop web application
EMI/EMC @ MIL-STD-461FCE102 · CS101 · CS114-116 · RE102 · RS103
Environmental @ MIL-STD-810GLow pressure, low temperature, fluid contamination, solar radiation, rain, humidity, fungus, salt fog, sand/dust, vibration, shock

Applications

Military Truck Platforms

Central PDU on rocket, air defence, and radar-mounted trucks

Mobile Command Centres

Uninterrupted power management for field command posts

Fixed Military Sites

Fixed power infrastructure for main and forward operating bases

Test & Maintenance Facilities

Multi-source distribution for depots and repair centres

MIL-STD Compliance

MIL-STD-461F

EMI/EMC
CE102CS101CS114CS115CS116RE102RS103

MIL-STD-810G

Environmental
Low PressureLow TemperatureContamination by FluidsSolar RadiationRainHumidityFungusSalt FogSand and DustVibrationShock

See Certifications & Quality for our test and validation approach, and our Test & Validation service for programme-specific testing.

Dimensions & Mechanical

Form factor4U × 19"
Height (4U)172 mm
Width483 mm
MountingBuilt-in rail
Depth602 mm
CoolingForced air (fan)

Datasheet

Need the technical datasheet?

The datasheet opens as soon as you submit the short form; our engineering team follows up with configuration guidance within 24 hours.

🔒 Your details are used only to follow up your documentation request — see our Privacy Notice.

To see all products in one file, open the Product Catalogue 2026 (PDF).

FAQ

Which voltage and source configurations does PDU-RT5002 support?+

The standard configuration operates with 3× 220 VAC 50 Hz inputs (UPS / Grid / Generator). Input priority is defined as 1. mains grid, 2. generator, and the output side provides up to ten 25 A AC/DC outputs.

How does automatic source transfer (ATS) work?+

PDU-RT5002 can receive power from UPS, mains grid, and generator sources; it primarily uses the mains grid and switches to the generator when necessary. Mains voltage, current, frequency, and output voltage are recorded in a log holding the last 100 records.

Which protocols does Ethernet remote monitoring support?+

Remote monitoring and control over Ethernet is provided through a desktop PC web application. Equipment powered from the PDU outputs can be monitored and managed remotely, and connected systems can be switched on and off based on internal temperature data. Mains voltage, current, frequency, and output voltage are logged.

Which platforms can it be mounted on?+

PDU-RT5002 is 19-inch 4U standard rack compatible, allowing direct installation in: fixed command centres, mobile command containers, tactical truck (6×6 / 8×8) power cabinets, radar stations, air-defence systems, naval platform rack units, and military data centre cabinets. Its built-in rail allows easy mounting, movement, and maintenance in rack-type cabinets.

What is the lead time and serial production capacity?+

Standard configurations have a lead time of 8–12 weeks. Customer-specific configurations (custom channel count, voltage level, alternative connector types) require an additional 3-6 weeks of engineering. Monthly serial-production capacity scales between 20-60 units.

Which certifications does it hold?+

MIL-STD-461F (EMI/EMC) and MIL-STD-810G (environmental — 11 methods). TEDEG holds NCAGE code TM885, an ISO 9001 quality management system and EYDEP registration, and is a member of the OSSA and SAHA Istanbul clusters.