Skip to content
Power Distribution Units (PDU)

PowerGuard MAR-2 Military Power Distribution Panel — Mains / Generator, 9 Fused Outputs

Product code

PWRGRD-GDPMARII

Input

220 VAC, 50 Hz

Source

Mains / generator — manual selector switch

Outputs

9 × 220 VAC, each fused

Protection

F1–F11 per-line fuses · separate N and PE

Switching

K1 / K2 contactor control

Safety

Guarded emergency stop button

Enclosure

EMI-gasketed, sealed, with rain roof

Body dimensions

380 × 602 × 188 mm (W × H × D)

Weight

14 ± 1 kg

MIL-STD-461FMIL-STD-810GITAR-FreeEAR99NCAGE: TM885

Overview

Product and Purpose

The PowerGuard MAR-2 Power Distribution Panel is a multi-output, protected AC power distribution solution that manages energy safely between mains and generator sources. It is designed to keep critical loads supplied without interruption, distribute power lines safely and give the operator direct control.

Its fuse groups, contactor structure and control elements supply different subsystems independently of one another. With a rain roof and an EMI-gasketed sealed enclosure, it is suitable for outdoor use and aimed at reliable operation in critical applications that require electromagnetic compatibility.

Engineering Capability

Input and source management:

  • Supply: 220 VAC, 50 Hz
  • Source type: Mains or generator
  • Source selection: Manual AC source selector switch for mains / generator changeover
  • Safety: Per-line protection and earth (PE) distribution

Output and protection architecture:

FeatureValue
Number of outputs9 × 220 VAC AC outputs
Output protectionEvery output independently fused (F1–F11, miniature circuit breakers)
N / PE distributionSeparate neutral and earth terminal for each output
SwitchingCentral control via K1 and K2 contactors
Load groupsElectrical isolation between groups
Cable cross-sectionsOptimised for different load requirements
Status monitoringLED indicators
Emergency stopGuarded emergency stop button

Separate supply lines for critical systems, plus communication and spare output provisions, are built into the panel.

Mechanical design:

FeatureValue
Body dimensions (W × H × D)380 × 602 × 188 mm
Width / depth including roof410 mm / 190 mm
Overall mounting envelope (W × H)474 × 632 mm (including side entry and cable glands)
MountingSlotted mounting brackets on both sides
Cable entriesCable glands on the bottom face
DoorLatched, EMI-gasketed sealed front door
Weight14 ± 1 kg

Typical Applications

  • Field and forward base power distribution: Fused distribution of 220 VAC from a generator or the grid to multiple subsystems
  • Shelter and container systems: Supplying mission equipment with per-line protection
  • Sites that need source changeover: Manual switch to the generator when mains power fails
  • EMI-sensitive applications: Outdoor distribution for critical systems that require electromagnetic compatibility

The TEDEG Advantage

MAR-2 brings source selection, per-line fuse protection, contactor control and emergency stop together in a single outdoor panel. Because every output has its own neutral and earth terminal, wiring errors and fault-finding in the field are easier. At 14 kg with slotted mounting brackets, it mounts quickly on a wall, pole or shelter surface.

Corporate assurance: TEDEG Defence is an approved supplier of ASELSAN, Roketsan and the Turkish Ministry of National Defence (MSB), with NATO supplier registration under NCAGE: TM885.

For higher-voltage (400 VAC) outdoor distribution see the Military AC Power Distribution Panel; for rack-mount distribution see PDU-RT5002.

Specifications

Product codePWRGRD-GDPMARII
Input220 VAC, 50 Hz
SourceMains / generator — manual selector switch
Outputs9 × 220 VAC, each fused
ProtectionF1–F11 per-line fuses · separate N and PE
SwitchingK1 / K2 contactor control
SafetyGuarded emergency stop button
EnclosureEMI-gasketed, sealed, with rain roof
Body dimensions380 × 602 × 188 mm (W × H × D)
Weight14 ± 1 kg

Datasheet

Need the technical datasheet?

Our engineering team shares the datasheet and configuration guidance within 24 hours.

Talk to Engineering

🔒 Your details are used only for documentation tracking — GDPR-compliant, never shared with third parties.

FAQ

What sources does MAR-2 run from?+

The panel runs from a 220 VAC, 50 Hz mains or generator source. Changeover between the two is done with the manual AC source selector switch on the front panel.

How many outputs does it have and how are they protected?+

There are 9 × 220 VAC outputs. All outputs are protected by independent fuses (F1–F11), and each output has its own neutral (N) and earth (PE) terminal. Load groups are electrically isolated from each other.

How are the outputs controlled?+

Outputs are managed centrally through K1 and K2 contactors. Status is shown by LED indicators, and in an emergency the supplies are cut with the guarded emergency stop button.

Can it be used outdoors?+

Yes. MAR-2 is designed for outdoor use in harsh conditions, with a rain roof and a latched, EMI-gasketed sealed front door. Cables enter through glands on the bottom face.

What are its dimensions and weight?+

Body dimensions are 380 × 602 × 188 mm (W × H × D); the overall mounting envelope including side entry and cable glands is 474 × 632 mm. Weight is 14 ± 1 kg. It mounts via slotted brackets on both sides.