Land Vehicles — Maintenance and Modernisation
Land Vehicle Fleet — 500 A Protection Against Reversed Batteries During Battery Changes
Reversed connections during field battery changes and jump-starts put alternators and vehicle electronics at risk. The PowerGuard TPB-01 Reverse Polarity Unit combines protection on battery lines up to 500 A with timed alternator shut-off. Its retrofit into the fleet's existing electrical installation is being assessed in an ongoing validation programme.
- Platform
- 6×6 / 8×8 military truck fleet — battery line, alternator and excite circuit (validation programme)
- Customer
- Leading Turkish Land Vehicle Maintenance and Modernisation Contractor
- Sector
- Land · military truck fleet
- Year
- 2024

Customer & Context
A leading Turkish land vehicle maintenance and modernisation contractor was maintaining a fleet of 6×6 and 8×8 military trucks and upgrading their electrical systems. Battery changes and jump-starts often took place in the field, under time pressure and in difficult conditions.
Field failure reports repeatedly identified the same cause: positive and negative terminals had been swapped during a battery change or jump-start. Current from a reversed battery could permanently damage the alternator and vehicle electronics. The truck then remained out of service until repairs were complete.
The contractor sent TEDEG Defence its technical requirements for a unit that could be added to the fleet's existing electrical installation. It needed to carry the battery line current, withstand engine-bay conditions and protect the alternator as well. The work began as a validation programme.
Challenge
The contractor's field failure reports and requirements document identified the following needs:
- Failures from reversed connections: incorrect connections during battery changes or jump-starts put the alternator and sensitive vehicle electronics at risk. Each failure left the truck out of service until repairs were complete.
- High-current battery line: the commercial diode modules evaluated did not meet the current requirement of the trucks' battery line. The protection unit had to carry this current while keeping energy loss low.
- Alternator protection: interrupting the battery line alone was insufficient. The alternator also needed protection from short circuits and overcurrent caused by reverse polarity. The existing solutions did not cover the alternator's excite line.
- Engine-bay conditions: the unit would face water, dust, vibration and a wide temperature range.
- Retrofit to existing vehicles: the solution had to connect to the fleet's existing electrical installation through standard connections, without waiting for new vehicle production.
The contractor wanted a single sealed unit to meet these needs.
TEDEG Solution
TEDEG Defence designed the PowerGuard TPB-01 Reverse Polarity Unit for the fleet's truck battery lines to meet the contractor's requirements. It combines reverse polarity protection and alternator shut-off time control in a single IP67 enclosure. Validation units have been delivered to the contractor.
An Internal Diode That Breaks the Circuit Within Milliseconds
TPB-01 works on 12 V and 24 V DC battery systems and has a current capacity of up to 500 A. Its internal diode technology detects reverse polarity and breaks the circuit within milliseconds, so the vehicle electronics and electrical system are protected against the current from a reversed battery. The internal diode keeps energy loss to a minimum during protection, and the unit is rated for the high current of the battery line.
Alternator Protection Through the Excite Line
The unit's time control shuts the alternator off 8 seconds after the excite signal drops. This delay prevents the alternator from being damaged by short circuits and overcurrent caused by reverse polarity, so the alternator is protected against a wrong battery connection as well as the vehicle electronics. Excite and control signals connect through the J1 4-pin circular connector, and battery line protection and alternator shut-off are handled in the same unit.
A Sealed Enclosure Added to the Existing Installation
The enclosure is black anodised aluminium, and its bolted, gasketed lid protects against the water, dust and vibration found on vehicles. The unit is rated IP67 and designed for −40 °C … +120 °C operation. The battery line enters through 2 × Pg21 metal cable glands, and the load / alternator line leaves through the glands on the opposite face. With standard terminal connections and a 151 × 176 mm flanged base, the unit bolts down at 4 points and is added to the existing vehicle electrical installation; overall height is 116.25 mm.
Outcome
Validation units have been delivered to the contractor, and fleet validation continues. The following points summarise product features:
- Current from a reversed battery is broken within milliseconds by the internal diode.
- The alternator is shut off 8 seconds after the excite signal drops, protecting it from short circuits and overcurrent.
- The protection suits battery lines up to 500 A on 12 V and 24 V DC systems.
- The unit is added to the existing installation with standard connections, without waiting for new vehicles.
- Battery line protection and alternator protection sit in a single IP67 enclosure.
Technical Scope
Values are taken from each product's own technical data; full specifications are on the product page.
- Operating voltage
- 12 V / 24 V DC
- Maximum current
- Up to 500 A
- Time control
- Alternator shut-off 8 s after excite drops
- Protection technology
- Internal diode
- Ingress protection
- IP67
- Operating temperature
- -40 °C to +120 °C
- Inputs
- 4 (Battery 1, Battery 2, Alternator, Battery charger)
- Busbar
- (+) and (−) 400 A
- Output fuses
- MIDI type, 30 / 60 / 100 A @28 VDC
- DC-DC converter
- 12 VDC → 28 VDC, 500 W
- Sealing
- MIL-STD-810G, Method 506.5, Procedure I
- Cable entries
- IP67 PG cable glands
More case studies

Military Land Vehicles · 2024
Military Truck — Two Batteries, Alternator and Charger on One 400 A Busbar
In place of scattered fuse boxes and battery wiring that changed from truck to truck on dual-battery 6×6 military trucks, a sealed distribution panel that brings four DC sources onto one busbar: the TDG-EDP-D0X.
Read case study
Armoured Land Vehicles · 2026
Pyrotechnically Actuated Safety System — Supercapacitor Backup Power Instead of a Lithium-Ion Battery
For a specification that called for a lithium-ion battery to back up a pyrotechnically actuated vehicle safety system, a supercapacitor-based solution that charges in the cold and delivers high momentary current: the PowerGuard EBB.
Read case study
Land Platforms · 2024
Tactical Truck Power Architecture Modernisation
An ageing PDU that could no longer keep pace with growing mission loads was replaced by a remotely monitored power distribution architecture built on the PDU-RT5002 and designed to MIL-STD requirements.
Read case study