PowerGuard MAR-2 Military Power Distribution Panel — Mains / Generator, 9 Fused Outputs
Product code
PWRGRD-GDPMARII
Input
220 VAC, 50 Hz
Source
Mains / generator — manual selector switch
Outputs
9 × 220 VAC, each fused
Protection
F1–F11 per-line fuses · separate N and PE
Switching
K1 / K2 contactor control
Safety
Guarded emergency stop button
Enclosure
EMI-gasketed, sealed, with rain roof
Body dimensions
380 × 602 × 188 mm (W × H × D)
Weight
14 ± 1 kg
Overview
Product and Purpose
The PowerGuard MAR-2 Power Distribution Panel is a multi-output, protected AC power distribution solution that manages energy safely between mains and generator sources. It is designed to keep critical loads supplied without interruption, distribute power lines safely and give the operator direct control.
Its fuse groups, contactor structure and control elements supply different subsystems independently of one another. With a rain roof and an EMI-gasketed sealed enclosure, it is suitable for outdoor use and aimed at reliable operation in critical applications that require electromagnetic compatibility.
Engineering Capability
Input and source management:
- Supply: 220 VAC, 50 Hz
- Source type: Mains or generator
- Source selection: Manual AC source selector switch for mains / generator changeover
- Safety: Per-line protection and earth (PE) distribution
Output and protection architecture:
| Feature | Value |
|---|---|
| Number of outputs | 9 × 220 VAC AC outputs |
| Output protection | Every output independently fused (F1–F11, miniature circuit breakers) |
| N / PE distribution | Separate neutral and earth terminal for each output |
| Switching | Central control via K1 and K2 contactors |
| Load groups | Electrical isolation between groups |
| Cable cross-sections | Optimised for different load requirements |
| Status monitoring | LED indicators |
| Emergency stop | Guarded emergency stop button |
Separate supply lines for critical systems, plus communication and spare output provisions, are built into the panel.
Mechanical design:
| Feature | Value |
|---|---|
| Body dimensions (W × H × D) | 380 × 602 × 188 mm |
| Width / depth including roof | 410 mm / 190 mm |
| Overall mounting envelope (W × H) | 474 × 632 mm (including side entry and cable glands) |
| Mounting | Slotted mounting brackets on both sides |
| Cable entries | Cable glands on the bottom face |
| Door | Latched, EMI-gasketed sealed front door |
| Weight | 14 ± 1 kg |
Typical Applications
- Field and forward base power distribution: Fused distribution of 220 VAC from a generator or the grid to multiple subsystems
- Shelter and container systems: Supplying mission equipment with per-line protection
- Sites that need source changeover: Manual switch to the generator when mains power fails
- EMI-sensitive applications: Outdoor distribution for critical systems that require electromagnetic compatibility
The TEDEG Advantage
MAR-2 brings source selection, per-line fuse protection, contactor control and emergency stop together in a single outdoor panel. Because every output has its own neutral and earth terminal, wiring errors and fault-finding in the field are easier. At 14 kg with slotted mounting brackets, it mounts quickly on a wall, pole or shelter surface.
Corporate assurance: TEDEG Defence is an approved supplier of ASELSAN, Roketsan and the Turkish Ministry of National Defence (MSB), with NATO supplier registration under NCAGE: TM885.
For higher-voltage (400 VAC) outdoor distribution see the Military AC Power Distribution Panel; for rack-mount distribution see PDU-RT5002.
Specifications
| Product code | PWRGRD-GDPMARII |
| Input | 220 VAC, 50 Hz |
| Source | Mains / generator — manual selector switch |
| Outputs | 9 × 220 VAC, each fused |
| Protection | F1–F11 per-line fuses · separate N and PE |
| Switching | K1 / K2 contactor control |
| Safety | Guarded emergency stop button |
| Enclosure | EMI-gasketed, sealed, with rain roof |
| Body dimensions | 380 × 602 × 188 mm (W × H × D) |
| Weight | 14 ± 1 kg |
Datasheet
FAQ
What sources does MAR-2 run from?+
The panel runs from a 220 VAC, 50 Hz mains or generator source. Changeover between the two is done with the manual AC source selector switch on the front panel.
How many outputs does it have and how are they protected?+
There are 9 × 220 VAC outputs. All outputs are protected by independent fuses (F1–F11), and each output has its own neutral (N) and earth (PE) terminal. Load groups are electrically isolated from each other.
How are the outputs controlled?+
Outputs are managed centrally through K1 and K2 contactors. Status is shown by LED indicators, and in an emergency the supplies are cut with the guarded emergency stop button.
Can it be used outdoors?+
Yes. MAR-2 is designed for outdoor use in harsh conditions, with a rain roof and a latched, EMI-gasketed sealed front door. Cables enter through glands on the bottom face.
What are its dimensions and weight?+
Body dimensions are 380 × 602 × 188 mm (W × H × D); the overall mounting envelope including side entry and cable glands is 474 × 632 mm. Weight is 14 ± 1 kg. It mounts via slotted brackets on both sides.