PowerGuard RCU-01 Remote Control Unit for Military PDUs — Remote ON/OFF, Sequenced Power-Up and Emergency Stop
Model
PowerGuard RCU-01
Part number (P/N)
TDG-049-01-A0000
Controls
Main power ON/OFF (sequenced) · ALL ON / ALL OFF · guarded emergency stop
Indicators
POWER (green) · UNIT OPEN (green) · FAULT (red)
Supply
18–36 VDC from the main unit over the interconnection cable; no separate supply
Interface
1 circular military connector (supply + RS-485); M5 ground stud
Interconnection cable
5 / 10 / 15 m
Ingress protection
IP65
Operating temperature
−32 °C … +50 °C
Weight
1 kg
Company:ITAR-FreeNCAGE: TM885
Overview
Product and Purpose
The PowerGuard RCU-01 is a compact remote control unit for military power distribution units. It is mounted away from the rack-mounted power distribution unit, for example next to the operator console on a ship or in a command space. System power is switched on and off in sequence from here and cut with a single action in an emergency.
It is used with the PowerGuard DC-PDCU-11 military DC power distribution and control unit, connects through a single military-connector interconnection cable and needs no separate supply. The unit is designed and manufactured by TEDEG in Ankara; the photos show a pre-production unit.
Engineering Capability
The RCU-01 brings the main-power and emergency-stop functions of the power distribution unit to the operator's position. When the main switch is set to ON (1), the power distribution unit is energised and the outputs come on with the programmed sequenced power-up delays; in the OFF (0) position the outputs are switched off in sequence and the main unit is then de-energised.
Pressing the mushroom-type emergency stop cuts the input and output power of the power distribution unit immediately. The system is re-energised when the button is released and the main switch is cycled off and on. Three LEDs show the operator the power, output and fault status. Supply (18–36 VDC) and RS-485 communication are carried on the same cable, and removable mounting lugs allow mounting on the platform or in a panel.
Technical specifications:
| Feature | Value |
|---|---|
| Controls | Main power switch ON / OFF; ALL ON / ALL OFF switch; mushroom-type emergency stop with yellow guard (latching) |
| Indicators | POWER (green), UNIT OPEN (green), FAULT (red) |
| Supply | From the main unit over the interconnection cable, 18–36 VDC; no separate supply required |
| Communication | RS-485 over the interconnection cable |
| Interface | 1 circular military connector (J1) on the rear face: supply + RS-485 |
| Interconnection cable | To the remote control connector (J5) of the power distribution unit; 5 / 10 / 15 m |
| Grounding | M5 ground stud on the rear face |
| Dimensions | 165 × 165 × 80 mm (excluding mounting lugs) |
| Mounting | Removable mounting lugs with slotted holes; platform or panel mounting |
| Weight | 1 kg |
| Ingress protection | IP65 |
| Paint | RAL 7038 polyurethane |
Front Face
| No | Element | Function |
|---|---|---|
| 1 | POWER LED (green) | The unit and the power distribution unit are energised |
| 2 | UNIT OPEN LED (green) | The outputs of the power distribution unit are on (sequenced power-up complete) |
| 3 | FAULT LED (red) | Fault or alarm in the power distribution unit |
| 4 | Main power switch ON / OFF | Energises / shuts down the power distribution unit in sequence |
| 5 | ALL ON / ALL OFF switch | Switches all output channels on / off |
| 6 | Emergency stop button | Mushroom button with yellow guard; cuts input and output power immediately |
Operating Logic
| Main switch | ALL ON / ALL OFF | Emergency stop | What happens |
|---|---|---|---|
| OFF → ON | – | Released | The power distribution unit is energised; outputs come on in sequence with the programmed delays |
| ON → OFF | – | Released | Outputs switch off in sequence with the programmed delays; the main unit is then de-energised |
| ON | ALL ON | Released | All channels switch on in the programmed sequence |
| ON | ALL OFF | Released | All channels switch off in the programmed sequence; the main unit stays energised |
| Any | Any | Pressed | Input and output power are cut immediately; FAULT LED lit |
| OFF → ON | – | Released again | The system re-energises after the button is released and the main switch is cycled off and on |
Environmental and EMC Design Basis
| Parameter | Value |
|---|---|
| Operating temperature | −32 °C … +50 °C |
| Storage temperature | −40 °C … +60 °C |
| Altitude | 0 – 3,000 m |
| Humidity | Designed to MIL-STD-810H Method 507.6 |
| Salt fog | Designed to MIL-STD-810H Method 509.7 |
| Vibration | Designed to MIL-STD-167-1A |
| Shock | Designed to MIL-STD-810F Method 516.5 |
| EMC | Designed to MIL-STD-461E surface-ship requirements |
Typical Applications
- Ships and surface platforms: main power and emergency stop of the rack-mounted power distribution unit at the operator console
- Command and control spaces: sequenced switch-on and switch-off of the mission systems from the operator's position
- Shelters: emergency stop and status indication near the operator, away from the equipment rack
- Operator console position: a single compact unit on the platform or in a panel, connected with one cable
Compatibility and Ordering Code
The RCU-01 is used with the PowerGuard DC-PDCU-11 through its J5 remote control connector. Ordering code: RCU-01-Cxx, where xx is the interconnection cable length in metres (C05 = 5 m, C10 = 10 m, C15 = 15 m). Example: RCU-01-C10: remote control unit with 10 m cable.
The TEDEG Advantage
One cable carries both supply and RS-485 communication, so the RCU-01 needs no separate power source at the operator position and installation stays simple. The DC-PDCU-11 and RCU-01 are designed together by TEDEG: the main switch on the RCU-01 follows the sequenced power-up and power-down delays programmed in the power distribution unit, and the latching emergency stop cuts its input and output power directly.
The full range of power distribution units is in Power Distribution Units (PDU); for project-specific remote control requirements, use the quote form.
Specifications
| Model | PowerGuard RCU-01 |
| Part number (P/N) | TDG-049-01-A0000 |
| Controls | Main power ON/OFF (sequenced) · ALL ON / ALL OFF · guarded emergency stop |
| Indicators | POWER (green) · UNIT OPEN (green) · FAULT (red) |
| Supply | 18–36 VDC from the main unit over the interconnection cable; no separate supply |
| Interface | 1 circular military connector (supply + RS-485); M5 ground stud |
| Interconnection cable | 5 / 10 / 15 m |
| Ingress protection | IP65 |
| Operating temperature | −32 °C … +50 °C |
| Weight | 1 kg |
| Dimensions | 165 × 165 × 80 mm (excluding mounting lugs) |
MIL-STD Compliance
MIL-STD-810H
EnvironmentalMIL-STD-810F
EnvironmentalMIL-STD-461E
EMI/EMCSee Certifications & Quality for our test and validation approach, and our Test & Validation service for programme-specific testing.
Datasheet
Engineering Support
Our engineering services can adapt this product to your platform, integrate it or test it against your programme requirements.
Quality and Testing
FAQ
Does it need a separate supply?+
No. The unit is powered from the power distribution unit over the interconnection cable (18–36 VDC), and the same cable carries the RS-485 communication.
How is the system restarted after an emergency stop?+
Release the emergency stop button, then switch the main switch off and on again. The power distribution unit re-energises with the programmed sequenced power-up.
Which units is it compatible with?+
It is used with the PowerGuard DC-PDCU-11 military DC power distribution and control unit, connected to its J5 remote control connector. The interconnection cable can be ordered in 5, 10 or 15 m lengths.
Where is it mounted?+
On the platform or in a panel with the removable mounting lugs, typically next to the operator console on a ship or in a command space.
What do the LEDs show?+
POWER (green) shows that the unit and the power distribution unit are energised, UNIT OPEN (green) shows that the outputs are on after the sequenced power-up, and FAULT (red) shows a fault or alarm in the power distribution unit.