PowerGuard RCU-01 Remote Control Unit for Military PDUs — Remote ON/OFF, Sequenced Power-Up and Emergency Stop

Model

PowerGuard RCU-01

Part number (P/N)

TDG-049-01-A0000

Controls

Main power ON/OFF (sequenced) · ALL ON / ALL OFF · guarded emergency stop

Indicators

POWER (green) · UNIT OPEN (green) · FAULT (red)

Supply

18–36 VDC from the main unit over the interconnection cable; no separate supply

Interface

1 circular military connector (supply + RS-485); M5 ground stud

Interconnection cable

5 / 10 / 15 m

Ingress protection

IP65

Operating temperature

−32 °C … +50 °C

Weight

1 kg

MIL-STD-810H (Environmental)MIL-STD-810F (Environmental)MIL-STD-461E (EMI/EMC)

Company:ITAR-FreeNCAGE: TM885

Overview

Product and Purpose

The PowerGuard RCU-01 is a compact remote control unit for military power distribution units. It is mounted away from the rack-mounted power distribution unit, for example next to the operator console on a ship or in a command space. System power is switched on and off in sequence from here and cut with a single action in an emergency.

It is used with the PowerGuard DC-PDCU-11 military DC power distribution and control unit, connects through a single military-connector interconnection cable and needs no separate supply. The unit is designed and manufactured by TEDEG in Ankara; the photos show a pre-production unit.

Engineering Capability

The RCU-01 brings the main-power and emergency-stop functions of the power distribution unit to the operator's position. When the main switch is set to ON (1), the power distribution unit is energised and the outputs come on with the programmed sequenced power-up delays; in the OFF (0) position the outputs are switched off in sequence and the main unit is then de-energised.

Pressing the mushroom-type emergency stop cuts the input and output power of the power distribution unit immediately. The system is re-energised when the button is released and the main switch is cycled off and on. Three LEDs show the operator the power, output and fault status. Supply (18–36 VDC) and RS-485 communication are carried on the same cable, and removable mounting lugs allow mounting on the platform or in a panel.

Technical specifications:

FeatureValue
ControlsMain power switch ON / OFF; ALL ON / ALL OFF switch; mushroom-type emergency stop with yellow guard (latching)
IndicatorsPOWER (green), UNIT OPEN (green), FAULT (red)
SupplyFrom the main unit over the interconnection cable, 18–36 VDC; no separate supply required
CommunicationRS-485 over the interconnection cable
Interface1 circular military connector (J1) on the rear face: supply + RS-485
Interconnection cableTo the remote control connector (J5) of the power distribution unit; 5 / 10 / 15 m
GroundingM5 ground stud on the rear face
Dimensions165 × 165 × 80 mm (excluding mounting lugs)
MountingRemovable mounting lugs with slotted holes; platform or panel mounting
Weight1 kg
Ingress protectionIP65
PaintRAL 7038 polyurethane

Front Face

NoElementFunction
1POWER LED (green)The unit and the power distribution unit are energised
2UNIT OPEN LED (green)The outputs of the power distribution unit are on (sequenced power-up complete)
3FAULT LED (red)Fault or alarm in the power distribution unit
4Main power switch ON / OFFEnergises / shuts down the power distribution unit in sequence
5ALL ON / ALL OFF switchSwitches all output channels on / off
6Emergency stop buttonMushroom button with yellow guard; cuts input and output power immediately

Operating Logic

Main switchALL ON / ALL OFFEmergency stopWhat happens
OFF → ON–ReleasedThe power distribution unit is energised; outputs come on in sequence with the programmed delays
ON → OFF–ReleasedOutputs switch off in sequence with the programmed delays; the main unit is then de-energised
ONALL ONReleasedAll channels switch on in the programmed sequence
ONALL OFFReleasedAll channels switch off in the programmed sequence; the main unit stays energised
AnyAnyPressedInput and output power are cut immediately; FAULT LED lit
OFF → ON–Released againThe system re-energises after the button is released and the main switch is cycled off and on

Environmental and EMC Design Basis

ParameterValue
Operating temperature−32 °C … +50 °C
Storage temperature−40 °C … +60 °C
Altitude0 – 3,000 m
HumidityDesigned to MIL-STD-810H Method 507.6
Salt fogDesigned to MIL-STD-810H Method 509.7
VibrationDesigned to MIL-STD-167-1A
ShockDesigned to MIL-STD-810F Method 516.5
EMCDesigned to MIL-STD-461E surface-ship requirements

Typical Applications

  • Ships and surface platforms: main power and emergency stop of the rack-mounted power distribution unit at the operator console
  • Command and control spaces: sequenced switch-on and switch-off of the mission systems from the operator's position
  • Shelters: emergency stop and status indication near the operator, away from the equipment rack
  • Operator console position: a single compact unit on the platform or in a panel, connected with one cable

Compatibility and Ordering Code

The RCU-01 is used with the PowerGuard DC-PDCU-11 through its J5 remote control connector. Ordering code: RCU-01-Cxx, where xx is the interconnection cable length in metres (C05 = 5 m, C10 = 10 m, C15 = 15 m). Example: RCU-01-C10: remote control unit with 10 m cable.

The TEDEG Advantage

One cable carries both supply and RS-485 communication, so the RCU-01 needs no separate power source at the operator position and installation stays simple. The DC-PDCU-11 and RCU-01 are designed together by TEDEG: the main switch on the RCU-01 follows the sequenced power-up and power-down delays programmed in the power distribution unit, and the latching emergency stop cuts its input and output power directly.

The full range of power distribution units is in Power Distribution Units (PDU); for project-specific remote control requirements, use the quote form.

Specifications

ModelPowerGuard RCU-01
Part number (P/N)TDG-049-01-A0000
ControlsMain power ON/OFF (sequenced) · ALL ON / ALL OFF · guarded emergency stop
IndicatorsPOWER (green) · UNIT OPEN (green) · FAULT (red)
Supply18–36 VDC from the main unit over the interconnection cable; no separate supply
Interface1 circular military connector (supply + RS-485); M5 ground stud
Interconnection cable5 / 10 / 15 m
Ingress protectionIP65
Operating temperature−32 °C … +50 °C
Weight1 kg
Dimensions165 × 165 × 80 mm (excluding mounting lugs)

MIL-STD Compliance

MIL-STD-810H

Environmental

MIL-STD-810F

Environmental

MIL-STD-461E

EMI/EMC

See Certifications & Quality for our test and validation approach, and our Test & Validation service for programme-specific testing.

Datasheet

Need the technical datasheet?

The datasheet opens as soon as you submit the short form; our engineering team follows up with configuration guidance within 24 hours.

🔒 Your details are used only to follow up your documentation request — see our Privacy Notice.

To see all products in one file, open the Product Catalogue 2026 (PDF).

FAQ

Does it need a separate supply?+

No. The unit is powered from the power distribution unit over the interconnection cable (18–36 VDC), and the same cable carries the RS-485 communication.

How is the system restarted after an emergency stop?+

Release the emergency stop button, then switch the main switch off and on again. The power distribution unit re-energises with the programmed sequenced power-up.

Which units is it compatible with?+

It is used with the PowerGuard DC-PDCU-11 military DC power distribution and control unit, connected to its J5 remote control connector. The interconnection cable can be ordered in 5, 10 or 15 m lengths.

Where is it mounted?+

On the platform or in a panel with the removable mounting lugs, typically next to the operator console on a ship or in a command space.

What do the LEDs show?+

POWER (green) shows that the unit and the power distribution unit are energised, UNIT OPEN (green) shows that the outputs are on after the sequenced power-up, and FAULT (red) shows a fault or alarm in the power distribution unit.