Solid-State vs Relay 28 VDC Power Distribution: Sequencing and Remote Control

TEDEG Defence Engineering Team · 25 November 2026 · 9 min read

PowerGuard DC-PDCU-11 Military DC Power Distribution and Control Unit

Solid-State vs Relay Power Distribution

If the loads in a 28 VDC cabinet switch on together, the bus voltage can drop and a sensitive load may reboot. For the engineer choosing solid-state vs relay power distribution, the question extends beyond the switch itself: where will protection, monitoring and sequencing sit, and how will the operator control the loads? Mechanical relays and contactors, or semiconductor-switched solid-state channels, are common options in system cabinets and shipboard mission racks.

In a relay, current flows through a contact. Switching wears the contact; DC arcing can shorten its life further, and operation is audible. A relay does not measure current by itself. Protection requires a fuse or breaker alongside it, while monitoring needs a separate module. A solid-state channel combines the switch, measurement and protection in the same circuit.

Consider the 19-inch 2U 28 VDC solid-state rack PDU PowerGuard DC-PDCU-11 and its operator-side companion, the RCU-01. The DC-PDCU-11 has no mechanical contactors or relays, so there is no contact wear and switching is silent. Each channel continuously measures current, voltage and temperature.

Channel Protection and the Total Current Limit

The DC-PDCU-11 provides 11 independent solid-state 28 VDC channels, each rated 20 A. Each channel has electronic over-current and short-circuit protection, with a voltage drop of 0.5 V maximum. Allow for this drop alongside cable losses when assessing voltage at the load.

The channel rating and the unit's total limit need separate checks. The published total output limit is 100 A (2,800 W at 28 VDC), adjustable in software. Multiplying 11 × 20 A does not give the unit a "220 A" rating. Check the load list against both limits:

  • Does each load's continuous and inrush current fit a single 20 A channel?
  • Is the sum of the loads running at the same time below the 100 A limit?

The 100 A input fuse is accessible from the front panel. Input protection is referenced to MIL-STD-1275E and covers reverse polarity, over-voltage, spikes and surges.

Fused Busbar or Solid-State Outputs?

Combining vehicle power sources and controlling individual mission loads in a cabinet call for different architectures. The comparison below shows where each product fits; the units are not interchangeable.

CriterionFused busbar: TDG-EDP-D0XSolid-state outputs: DC-PDCU-11
Main jobCombining 4 sources in a vehicle (2 batteries, alternator, battery charger)Channel-by-channel control of 28 VDC loads in a rack
Distribution(+) / (−) 400 A busbar; MIDI-fused outputs (30 / 60 / 100 A @ 28 VDC)11 × 20 A solid-state channels; 100 A total
SwitchingInput and load contactors, emergency stop, battery isolatorElectronic switch per channel; front panel, web, TCP/IP, RCU-01
After a faultFuse replacement (spare MIDI fuses)Channel reset from the web interface
MechanicalAluminium enclosure, 14 ± 2 kg19-inch 2U, 9 ± 2 kg

The 400 A rating of the military vehicle DC power distribution unit applies to its busbar, not an individual output. In a fused design, the fuse protects the cable. Our DC busbar guide explains how to match the fuse rating to the cable cross-section. Many systems use both architectures: the busbar combines sources, while the solid-state unit manages mission loads.

Sequenced Power-Up for 28 VDC Loads

Most mission loads have capacitive inputs, including DC-DC converters, displays and computers. Energising them together can stack their inrush peaks, briefly collapse the bus voltage and cause sensitive loads to reboot.

Sequenced power-up for 28 VDC loads separates their start-up times. On the DC-PDCU-11, each channel's power-up and power-down delay is programmable with 10 ms resolution. An ALL ON / ALL OFF or main power command switches the channels in the programmed order. A typical sequence is:

  1. 1.Infrastructure first: network switch and monitoring loads.
  2. 2.High-inrush loads next, with delays between them.
  3. 3.Reverse the order at shutdown: mission loads first, infrastructure last.

Verify the delays in the field against the loads' actual start-up profiles.

Control Paths: Front Panel, Web, TCP/IP and LOCAL/REMOTE

DC-PDCU-11 channels can be switched from the front-panel buttons, the embedded web interface, an integrated system using the Ethernet TCP/IP control protocol, or the optional RCU-01. The web control page shows DC bus voltage, total current and the number of channels on. Its channel table displays each channel's temperature, input/output voltage and current. A password-protected settings page holds the alarm thresholds, delays and total current limit.

These control paths need a clear priority. The front-panel LOCAL / REMOTE selection sets it: in REMOTE mode, commands come from the web interface, TCP/IP and the remote control unit. During maintenance, selecting LOCAL prevents a remote command from energising the channel being worked on.

Remote Emergency Stop at the Operator Console with the RCU-01

When the rack is away from the operator, the emergency stop needs to be within reach at the console. The PDU remote control unit PowerGuard RCU-01 mounts beside the operator console and connects to the DC-PDCU-11's J5 connector.

  • Main power ON/OFF: ON switches the outputs on in sequence with the programmed delays; OFF switches them off in sequence, then removes power from the main unit.
  • ALL ON / ALL OFF: switches all channels on or off in the programmed order; the main unit stays energised.
  • Emergency stop: a latching mushroom button with a yellow guard immediately cuts input and output power of the main unit.
  • One cable: 18–36 VDC supply and RS-485 share the cable, so no separate supply is needed; cable lengths are 5, 10 or 15 m.

The RCU-01 is rated IP65 and operates from −32 °C to +50 °C. POWER, UNIT OPEN and FAULT LEDs indicate power, output and fault status at the operator console.

Alarm Behaviour and Bypass

DC-PDCU-11 alarm thresholds are adjustable in software. The defaults are bus voltage > 30 V or < 20 V, internal temperature > 53 °C or < 0 °C, and communication loss of approximately 10 s. An alarm cuts the outputs.

The BYPASS switch allows loads to keep running during an alarm. In the ON position, the outputs are not interrupted and the BYPASS LED lights. Enabling bypass is an operational decision: the procedure should specify who may do so and under what conditions. The emergency stop cuts all outputs immediately.

Selection Checklist

Prepare these seven points alongside the load list before selecting a solid-state 28 VDC distribution unit. Our guide on how to specify a military PDU covers the general specification clauses.

  1. 1.Channel count and rating: 11 × 20 A standard; can be adapted to project requirements.
  2. 2.Total current: simultaneous load sum against the published 100 A limit.
  3. 3.Input arrangement: number of inputs and connector type.
  4. 4.Connectors: pin assignment and channel-to-connector mapping are given in the ICD.
  5. 5.Communication: Ethernet TCP/IP standard; additional interfaces on request.
  6. 6.Remote control: is an RCU-01 needed, and how long is the cable?
  7. 7.Mounting and environment: 19-inch 2U, 500 mm deep, IP54, −32 °C to +50 °C; designed to MIL-STD-810H, 461E and 167-1A.

For AC rack architectures with automatic transfer, see the military PDU guide. For multi-source 220 VAC distribution, see the PDU-RT5002 page.

Frequently Asked Questions

Is solid-state power distribution better than relays?

The application determines the choice. Solid-state channels provide per-channel measurement, electronic protection, silent switching and programmable sequencing. For combining heavy current from several vehicle sources, a fused busbar and contactor architecture remains a natural choice.

Does 11 × 20 A mean 220 A in total?

No. The DC-PDCU-11 has a per-channel rating of 20 A and a published total output limit of 100 A (2,800 W at 28 VDC). The total current limit is adjustable in software.

Why sequence 28 VDC loads at power-up?

Simultaneous inrush peaks from capacitive-input loads can collapse the bus. A per-channel delay with 10 ms resolution brings the loads on one after another.

Does a remote emergency stop need its own supply?

The RCU-01 does not. It draws 18–36 VDC from the main unit through the interconnection cable, which also carries the RS-485 link.

From the Load List to the Configuration

Solid-state 28 VDC distribution combines protection, monitoring, sequencing and remote control in one rack unit. Start with the per-channel and total current requirements, then define the control paths and the emergency stop location relative to the operator. The military power distribution units category covers the full product family. Share the load list and channel requirements through the quote form to define the DC-PDCU-11 and RCU-01 configuration with our engineering team.