One Motor Type, Four Different Loads
The levelling legs of a missile vehicle, the antenna mast on a radar vehicle, a rotating radar antenna and a weapon pedestal: all four are often moved by a three-phase induction motor. The military induction motor drive has a different job in each case: holding the load during levelling, stopping the mast safely at its end positions, maintaining steady radar speed with a high-inertia load, or positioning the pedestal accurately.
Load profile, control, the safety chain and communication define the requirements in each application. TEDEG's Mil-Drive-55 military induction motor drive provides the examples. For the off-the-shelf vs custom decision, see off-the-shelf industrial VFD or a custom military motor drive?, and for FOC and STO, see our military motor drive guide.
Four Questions That Define the Application
Define the application for the drive through four questions:
- 1.How does the load behave? Is it constant or variable? What are its mass and inertia, and can the load drive the motor?
- 2.What is being controlled? Speed and torque only, or position as well?
- 3.What does the safety chain require? Safe torque off, emergency stop, a brake, end-position information.
- 4.What does the control computer expect? Commands, status and fault data, response time.
On the Mil-Drive-55, speed and torque control are standard: sensorless FOC, torque limiting and torque-based stop, and autotune. Closed-loop speed and position control with encoder or resolver feedback is a project option. This distinction determines which applications require additional hardware.
Vehicle Levelling Systems
At its operating position, a vehicle carrying a missile system or radar settles onto legs to level its body. The leg motors raise and lower the vehicle.
Load profile
Speed is low and torque is high. The load is light until a leg touches the ground. The vehicle's weight then loads the leg, and torque rises quickly. Stopping the motor does not remove the load: the leg continues to support the vehicle.
Control and safety
Torque limiting and torque-based stop serve this application: when a leg settles on the ground or reaches its mechanical end, the motor stops without overload. Once it has stopped, the motor holding brake carries the load. The Mil-Drive-55 has a 24 VDC brake output that the drive switches and monitors for current. Two-channel STO and the emergency stop input connect to the safety chain.
Communication
The control computer manages the legs individually or together. Each drive has its own address on the RS-485 line, which carries operating status, fault codes and limit-switch information. If the axes must move as a coordinated group, a multi-axis master/slave arrangement is available as a project option.
Antenna Elevating Masts
A telescopic mast lifts an antenna or sensor head above the vehicle in several stages.
Load profile
The vertical load is raised against gravity. Wind load and sway increase as the mast extends. During lowering, the load tries to drive the motor, returning energy to the DC bus.
Control and safety
Smooth starts and stops protect the structure and antenna. On the Mil-Drive-55, ramps are adjustable from 0.1 to 600 s, and two independent ramp sets can be selected. Dynamic braking absorbs the energy returned during lowering: an internal brake chopper and internal brake resistor are standard, and an external brake resistor can be connected through the KN6 connector. When the mast stops, the holding brake keeps it in place. End positions are usually defined by limit switches; if the mast must stop at an intermediate height, position control with encoder feedback is added as a project option.
Communication
The mast is subject to the control computer's interlocks: it must not rise while the vehicle moves, and the vehicle must not move while it is up. These interlocks are defined in the I/O list and the communication data map.
Radar Antenna Positioning
A mobile radar antenna may rotate continuously or scan a defined sector.
Load profile
Mass and inertia are large. Torque demand peaks during acceleration and deceleration; at constant speed, wind load and bearing friction dominate. When slowing down, the stored energy returns to the drive.
Control and safety
For an antenna turning at constant speed, sensorless FOC speed control is often sufficient. Holding the antenna in a given direction requires position feedback, available with an encoder or resolver as a project option. Dynamic braking handles deceleration. Electromagnetic emissions matter because the drive operates next to the radar: the Mil-Drive-55 is designed to MIL-STD-461F, and an input EMI filter and an output filter are standard.
Communication and supply
A radar group often needs a 400 Hz supply as well. Our 115 VAC 400 Hz power supply selection guide covers this choice. One example is the PowerGuard 115/200 VAC 400 Hz static frequency converter. The closing case study describes the motor drive and supply on one platform.
Turret and Pedestal Drives
A weapon or sensor pedestal moves in azimuth and elevation.
Load profile
Movements are short, frequent and reversing. Torque demand is high at each start and reversal; near the target, motion must be slow and precise.
Control and safety
Position control is most prominent in this application: closed-loop speed and position control with encoder or resolver feedback is added as a project option. The comparison between an induction motor with FOC and a servo is covered in our FOC guide. Two-channel STO and the emergency stop input cut motor torque in an emergency. STO does not isolate the motor from the supply; for work on the motor or its cables, the supply must be disconnected separately.
Communication
Commands come from the platform's control computer. The standard interface is Modbus RTU; CAN/CANopen and Ethernet are project options.
The Four Applications Compared
| Application | Load profile | Control | Safety and brake | Key need |
|---|---|---|---|---|
| Vehicle levelling | Low speed, high torque, load remains at standstill | Speed + torque; torque-based stop | STO, holding brake, limit switches | Holding the load |
| Antenna mast | Vertical load, wind, regeneration when lowering | Speed + ramps; encoder for intermediate positions | Holding brake, dynamic braking, interlocks | Safe end positions |
| Radar antenna | High inertia, continuous or sector rotation | Speed; encoder/resolver for holding a bearing | Dynamic braking, EMC | Steady speed |
| Turret and pedestal | Short, frequent, reversing moves | Closed-loop speed + position | STO, emergency stop | Accurate position |
Integration with the Control Computer
In all four applications the drive is connected to the platform's control computer. The Mil-Drive-55 communicates over 2 × isolated RS-485 (Modbus RTU), and up to 63 drives can share one line. If communication is lost, the motor stops by coasting or on a ramp after the selected watchdog time (30, 300, 1,000 or 3,000 ms). The communication data map is adapted to the project.
The drive has an IP67 sealed, fanless enclosure, operates from −40 °C to +55 °C and delivers full rated power up to +55 °C. All interfaces are on MIL-DTL-38999 series connectors. For applications requiring the drive, power distribution and interlock/limit logic in one box, the Mil-Drive MCU-400 military motor control unit is another option.
Military Induction Motor Drive Manufacturer in Turkey: TEDEG Defence
TEDEG Defence is based in Ankara and designs and manufactures military power electronics and motor drives.
| Profile | Details |
|---|---|
| Company | TEDEG Savunma Sanayi A.Ş. (brand: TEDEG Defence) |
| Headquarters | Ankara, Türkiye |
| Founded | 2023 |
| Registrations and certificates | ISO 9001, EYDEP |
| Cluster membership | SAHA Istanbul |
The Mil-Drive-55 is supplied to ROKETSAN, ASELSAN and KOLUMAN. Applications in service include the levelling legs of an armoured missile vehicle, an antenna elevating platform and a radar vehicle. Each drive is configured for the platform's motor, I/O and communication data map; it is not an off-the-shelf product.
Frequently Asked Questions
Why does a vehicle levelling system need torque limiting in the motor drive?
When a leg settles on the ground or reaches its mechanical end, motor current rises sharply. With torque limiting and torque-based stop, the drive stops at that point without overloading the motor or mechanism. The holding brake then carries the load.
Can an induction motor drive provide position control for a radar antenna?
Yes. Sensorless FOC is often sufficient for constant-speed rotation. Holding the antenna at a given bearing uses closed-loop position control with encoder or resolver feedback. This is a project option on the Mil-Drive-55.
Why does an antenna mast need dynamic braking?
When the mast is lowered, the load drives the motor and energy returns to the DC bus. Dynamic braking dissipates this energy in a brake resistor. The Mil-Drive-55 has an internal brake chopper and resistor as standard, with an external resistor connected through KN6.
Can several motor drives be controlled on the same line?
Yes. The Mil-Drive-55 Modbus address is set from 1 to 63, so up to 63 drives can share one RS-485 line. Coordinated multi-axis master/slave motion is a project option.
Describe Your Application
Levelling systems, antenna masts, radars and pedestals use the same motor type but place different demands on the drive. Describing the load profile, control, safety and communication requirements makes the distinction between standard functions and project options clear. Other models are in the military motor drives and military frequency converters categories. Download the Mil-Drive-55 operating manual and technical overview from the technical documents section of the product page, and send your motor and application data through the quote form.
Field example: the air-defence pedestal case study describes the pedestal's azimuth/elevation drive and the radar's 400 Hz supply in one application.